Now Open - New Branch of City Irrigation Ltd at Charlcroft Nurseries, Charlcraft Lane, Bognor Regis, PO21 5TS. To check stock at Bognor please phone : 01243 827178 for other enquireies please contact us on 020-8462-4630
Applications To restore system pressure, when the mains supply is insufficient a pump may be used, owever, to comply with water authority byelaws a break tank must be incorporated, as the pump is recluded from direct connection to the mains water supply.
The ESPA Sub-tank system has been designed to solve this problem. A fully automatic unit, the Sub-tank has an Acuaria stainless steel submersible pump incorporated into the break tank giving space saving advantages in small plant rooms or roof spaces. (see BOREHOLE PUMPS > Acuaria for details of pump) Control is provided by a constant pressure device, with built in pressure gauge (PRESSURISATION >Kit02/05/Press for details of control device) Electronics prevent starting without water, LED's display On line, Pump operating and Fault. Installation is straightforward with only three connections required.
* LED indicators display line voltage, pump operation and Failure. * Does not require any or maintenance or pre-charge. * Adjustable start pressure:- 1.5 - 2.5 Bars * 95 Ltr or 227 Ltr Actual capacity high density polyethylene break tank (BS4213). WRAS approved. * Byelaws 30 top tank fitted with 1/2 ball valve complying with (byelaw 11) type A air gap, protecting incoming mains supply from class 1 and class 5 designated risk of contamination (byelaws 25). * Kit 05 Pressure stat starts and stops pump automatically and supplies water at a constant pressure. * Pressure switch with vessel options available, please add £30. * Maximum temperature 35°C. * WRAS Listing Applied 2007